Compare commits

..

2 Commits

Author SHA1 Message Date
Codex
503a225ca6 fix(infra): pin virtio-container-disk to v1.8.2 (containerd 2.1 manifest fix)
KubeVirt v1.4.0 + RKE2 containerd 2.1.5 cannot pull
quay.io/kubevirt/virtio-container-disk:latest:
  rpc error: code = Unimplemented
  desc = failed to pull and unpack image: not implemented:
  media type "application/vnd.docker.distribution.manifest.v1+prettyjws"
  is no longer supported since containerd v2.1, please rebuild the image as
  "application/vnd.docker.distribution.manifest.v2+json" or
  "application/vnd.oci.image.manifest.v1+json"

The :latest tag was last rebuilt with the v1 manifest schema. Tagged versions
v1.6.5+, v1.7.3, v1.8.2 are rebuilt with v2/OCI manifests.

Pinning to v1.8.2 (newest available, contains current Windows VirtIO drivers).
The image only contains the Windows VirtIO driver ISO mounted as a CDROM —
not the KubeVirt runtime — so it is decoupled from the cluster KubeVirt
version.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-08 13:28:03 -05:00
Codex
63c3753111 feat(infra): activate ci1 VM — running:true + 10Gi ISO PVC + 1P password
Phase 1 prereqs all satisfied:
- Multus CNI v4.2.2 thick-plugin DS Running on rke2-server/agent1/agent2
- CDI v1.65.0 operator + CR Deployed (cdi-apiserver/deployment/uploadproxy
  all Running 1/1)
- Windows Server 2025 ISO (7.7GiB, March 2026 update) uploaded via CDI
  virtctl image-upload to PVC windows-server-2025-iso. Verified via PVC
  annotations: cdi.kubevirt.io/storage.condition.running.message="Upload
  Complete", storage.pod.phase="Succeeded"
- Local Administrator password generated (26 char, FANTASTIC strength).
  Stored in 1Password vault IAmWorkin (qaphopopkryhbg353ukzhhuqoq) item
  h3ix4mgfk65gmkcmvh6ly3d3hu. UTF-16-LE base64 in autounattend.xml Value
  field matches the 1P "autounattend AdministratorPassword Value" field.

Changes:
- ISO PVC bumped 6Gi → 10Gi (ISO is 7.7GiB, need headroom)
- Added labels app=ci-runner, flowercore.io/managed-by=bluejay-infra
- autounattend.xml AdministratorPassword Value: real base64-encoded password
- spec.running: false → true (VM starts on next ArgoCD sync)
- Header comment refreshed to LIVE state with prereq references

Network: still pod-network masquerade. Multus NAD prod-vlan57 is registered
but the VM doesn't use it yet (Phase 1.5 host bridge needed first).

Verify after sync:
  kubectl --kubeconfig $env:USERPROFILE\.kube\rke2.yaml -n kubevirt-vms get vm,vmi
  virtctl --kubeconfig $env:USERPROFILE\.kube\rke2.yaml vnc ci1 -n kubevirt-vms

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-08 13:24:25 -05:00
3 changed files with 13 additions and 201 deletions

View File

@@ -58,7 +58,7 @@ spec:
nodeName: rke2-server
containers:
- name: web
image: localhost/fc-updater-web:v20260508-pub3-deepening-2bdf108
image: localhost/fc-updater-web:v20260507-public-privacy
imagePullPolicy: Never
ports:
- containerPort: 8080

View File

@@ -6,14 +6,6 @@
# `bluejay-ws-sandbox-1` runner placeholder. Andrew explicitly does NOT want
# BLUEJAY-WS registered as a runner (workstation has personal/operator state).
#
# Storage layout (2026-05-08):
# * ISO is now sourced from Synology NFS (Path B) — see
# win2025-iso-nfs-pv.yaml. The Longhorn Filesystem PVC
# `windows-server-2025-iso` below is RETAINED but UNUSED so the prior
# CDI upload state is preserved as a fallback (and so ArgoCD doesn't
# prune it on this commit). It can be deleted in a follow-up commit
# after the NFS path is proven on a successful Windows install.
#
# Status (2026-05-08): LIVE — Phase 1 prereqs satisfied:
# * Multus CNI v4.2.2 thick-plugin DaemonSet running on all 3 RKE2 nodes
# (apps/multus/multus.yaml; ApplicationSet `infra-multus` Synced/Healthy)
@@ -58,34 +50,16 @@ metadata:
---
# ISO PVC — populated via CDI virtctl image-upload (CDI is now installed).
#
# **Volume mode (2026-05-08 status):** Filesystem-mode PVC. A migration to
# `volumeMode: Block` via DataVolume was attempted to address an OVMF SATA
# CDROM read timeout, but CDI v1.65.0's upload-target pod runs as uid 107
# with `capabilities.drop: [ALL]` and cannot open the underlying block
# device (`blockdev: cannot open /dev/cdi-block-volume: Permission denied`).
# Reverted to Filesystem PVC pending one of:
# - CDI deployment override granting CAP_SYS_RAWIO to upload pod
# - Pre-populated PVC via privileged init pod that dd's the ISO directly
# - Migration to a different storage class that exposes block devices
# differently (e.g. iSCSI, where Longhorn's CSI mount path may behave
# differently)
#
# Population workflow (this PVC, Filesystem mode):
# Population workflow (LIVE 2026-05-08):
# 1. virtctl --kubeconfig $env:USERPROFILE\.kube\rke2.yaml image-upload pvc \
# windows-server-2025-iso -n kubevirt-vms \
# --image-path "$env:USERPROFILE\Downloads\en-us_windows_server_2025_updated_march_2026_x64_dvd_8e06425a.iso" \
# --size 10Gi --storage-class longhorn --access-mode ReadWriteOnce \
# --uploadproxy-url https://localhost:8443 --insecure
# (--uploadproxy-url uses port-forward in practice: `kubectl port-forward
# -n cdi service/cdi-uploadproxy 8443:443 &` first.)
# --uploadproxy-url https://cdi-uploadproxy.cdi.svc:443 --insecure
# (--uploadproxy-url uses port-forward in practice: see plan doc Phase 1.5.)
#
# **Open boot issue:** even with the ISO at bootOrder:1, OVMF console showed:
# BdsDxe: starting Boot0001 "UEFI QEMU DVD-ROM QM00001 " from ... Sata(...)
# BdsDxe: failed to start Boot0001 ... Time out
# Diagnosis confirmed PVC content IS a valid bootable ISO9660 image — the
# timeout is in OVMF reading from the SATA-CDROM-backed-by-filesystem-PVC.
# Block mode would likely fix it; see CDI permission issue above.
# Note: CDI's PVC creation hooks add cdi.kubevirt.io/storage.* annotations
# automatically. The ISO source file is 7.7GB → request 10Gi for headroom.
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
@@ -99,7 +73,7 @@ spec:
- ReadWriteOnce # Bump to ReadOnlyMany after population for multi-VM use
resources:
requests:
storage: 10Gi # Server 2025 ISO is 7.7GB; 10Gi for headroom
storage: 10Gi # Bumped from 6Gi (Server 2025 ISO is 7.7GB)
storageClassName: longhorn
---
@@ -309,33 +283,7 @@ metadata:
role: github-actions-runner
flowercore.io/managed-by: bluejay-infra
spec:
# `running: true` is deprecated in favor of `runStrategy`. They are mutually
# exclusive — KubeVirt's validating webhook rejects any VM that sets both:
# admission webhook "virtualmachine-validator.kubevirt.io" denied the request:
# Running and RunStrategy are mutually exclusive.
# `Always` keeps a VMI running and restarts it if it crashes/exits — same
# semantics as the old `running: true`.
#
# **2026-05-08 status: VM cannot start due to a stale QEMU flock on the
# rootdisk PVC** (qemu reports `Failed to get "write" lock` on
# `/var/run/kubevirt-private/vmi-disks/rootdisk/disk.img`). The flock was
# left by a previous QEMU process during a force-deleted launcher pod
# cycle. Recovery requires either (a) a Longhorn engine restart on
# rke2-agent2, (b) a Longhorn volume detach via the longhorn-manager API
# (kubectl patch on `volume.longhorn.io/<pvc-name>` does not work — the
# spec.nodeID is reconciled back), or (c) a node reboot of rke2-agent2.
#
# **Confirmed working:** the bootOrder swap (windows-iso=1, rootdisk=2)
# and the runStrategy migration (above). The ISO PVC was successfully
# repopulated via virtctl image-upload pvc on the Filesystem-mode PVC.
#
# **Open: SATA CDROM read timeout** — even with bootOrder=1, OVMF reported
# `BdsDxe: failed to start Boot0001 ... Time out` reading the SATA CDROM
# backed by the Filesystem-mode PVC. A switch to Block-mode DataVolume
# was attempted but blocked by a CDI v1.65.0 upload-pod permission issue
# (capability drop prevents writing to the underlying block device).
# See header docstring on the ISO PVC.
runStrategy: Always # LIVE — ISO uploaded 2026-05-08, password in 1P
running: true # LIVE — ISO uploaded 2026-05-08, password in 1P
template:
metadata:
labels:
@@ -381,34 +329,14 @@ spec:
devices:
tpm: {} # Non-persistent vTPM — sufficient for runner; no BitLocker
disks:
# bootOrder: ISO must be 1 for first-boot install (the rootdisk has no
# EFI bootloader yet). After Windows installs, it writes its own UEFI
# Boot#### entries pointing at the rootdisk's EFI partition; UEFI then
# boots from rootdisk going forward and the ISO at bootOrder:2 acts as
# a fallback for re-install scenarios.
#
# Original (broken) order had rootdisk=1, windows-iso=2 — UEFI tried
# the empty virtio disk first, got nothing, fell back to the SATA
# CDROM at Boot0001 with a short timeout, and timed out before the
# CDROM enumerated. Console showed:
# BdsDxe: failed to start Boot0001 ... Time out
# BdsDxe: No bootable option or device was found.
# Confirmed via debug pod: PVC content IS a real bootable ISO9660
# (file: "ISO 9660 CD-ROM filesystem data ... (bootable)"), so the
# only bug was boot priority.
# 2026-05-08 PM: cdrom bus flipped sata→scsi for windows-iso to address
# the OVMF SATA-CDROM read timeout (`BdsDxe: failed to start Boot0001 ...
# Time out`). The SCSI CDROM uses virtio-scsi controller which has a
# longer read window and works cleanly on Filesystem-backed PVCs.
# See diagnostic chain in HANDOFF.md / CODEX-STATUS.md "OPEN — ci1".
- name: windows-iso
bootOrder: 1
cdrom:
bus: scsi
- name: rootdisk
bootOrder: 2
bootOrder: 1
disk:
bus: virtio
- name: windows-iso
bootOrder: 2
cdrom:
bus: sata
- name: virtio-drivers
cdrom:
bus: sata
@@ -435,23 +363,6 @@ spec:
persistentVolumeClaim:
claimName: ci1-rootdisk
- name: windows-iso
# 2026-05-08 PM: REVERTED from NFS Path B back to the original CDI
# Longhorn Filesystem PVC. NFS Path B (commit fc2aca0) failed at the
# storage layer because the Synology export `/volume1/ISOs` denies
# non-root client UIDs at the directory level (qemu uid 107 cannot
# `ls /iso/` even with file mode 0777). Confirmed via uid-107 +
# uid-0 busybox probe pods on rke2-agent2 — same export-only-root
# pattern as `/volume1/kubernetes` documented in
# `feedback_synology_nfs_kubernetes_export_root_only`. Memory:
# `feedback_synology_iso_export_root_only_uid_107_denied.md`.
#
# The Longhorn PVC `windows-server-2025-iso` (CDI Filesystem mode,
# 10Gi) was confirmed to contain valid ISO bytes that uid 107 CAN
# read (mode 0660 root:107). The OVMF SATA-CDROM read timeout from
# the original Path A is now addressed by the `bus: scsi` swap on
# the disks block above. The NFS PVC + PV are RETAINED on disk so
# the Path B state is recoverable; they can be pruned in a
# follow-up commit once SCSI boot is proven.
persistentVolumeClaim:
claimName: windows-server-2025-iso
- name: virtio-drivers

View File

@@ -1,99 +0,0 @@
# =============================================================================
# Windows Server 2025 ISO — Static NFS PV (Path B for SATA-CDROM timeout)
# =============================================================================
# Purpose: Mount the ISO from Synology NAS via NFS instead of from a Longhorn-
# backed Filesystem PVC.
#
# Why: SATA-CDROM emulation reading from a Longhorn-backed Filesystem PVC is
# too slow for OVMF's boot read window — the DVD-ROM enumeration times out
# before the bootloader can be read. Symptom on the serial console:
# BdsDxe: failed to start Boot0001 "UEFI QEMU DVD-ROM QM00001 " from ...
# BdsDxe: failed to start Boot0001 ... Time out
# BdsDxe: No bootable option or device was found
# Diagnosis confirmed the ISO content is a perfectly valid bootable ISO9660
# image — the bug is in the timing path between OVMF and Longhorn-backed
# storage, not in the ISO itself.
#
# Block-mode PVC was tried (`volumeMode: Block` via DataVolume) and would
# likely fix the timing, but CDI v1.65.0's upload-target pod cannot open the
# block device due to runAsUser:107 + capabilities.drop:[ALL] and we got:
# blockdev: cannot open /dev/cdi-block-volume: Permission denied
#
# NFS-mounted ISO bypasses both issues: no Longhorn slowness, no CDI upload
# pod permission concerns. The ISO is read directly from the NAS over a
# native NFSv4.1 mount that QEMU's SATA emulator can read at full LAN speed.
#
# Layout on Synology:
# /volume1/ISOs/ (existing export, RKE2 ACL)
# en-us_windows_server_2025_updated_march_2026_x64_dvd_8e06425a.iso
# win2025-iso-disk/ (new subdir, 2026-05-08)
# disk.img -> hardlink to ../en-us_windows_server_2025_..._8e06425a.iso
#
# KubeVirt's launcher pod expects a PVC mounted at
# /var/run/kubevirt-private/vmi-disks/<diskName>/disk.img — by mounting the
# `win2025-iso-disk/` subdir as the NFS PV root, `disk.img` lives at the PV's
# root and KubeVirt's CDROM emulator finds it without any path manipulation.
#
# A symlink would NOT work for sub-path NFS mounts (the relative target
# `../...iso` falls outside the sub-mount root). A hardlink works because it
# references the same inode regardless of mount point.
#
# Memory references:
# - feedback_synology_nfs_volume1_kubernetes_export_scoped (Synology export
# scoping pattern — but /volume1/ISOs export, unlike /volume1/kubernetes,
# does support sub-path mounts because Synology NFS is configured with
# pseudo-fs in NFSv4.1)
# - feedback_kubevirt_iso_first_install_bootorder_and_runstrategy (boot
# order / runStrategy gotchas, separate from the storage timing issue)
#
# Validation (2026-05-08, from rke2-server / rke2-agent1 / rke2-agent2):
# mount -t nfs -o nfsvers=4.1,ro 10.0.58.3:/volume1/ISOs/win2025-iso-disk /tmp/m
# file /tmp/m/disk.img
# -> ISO 9660 CD-ROM filesystem data 'SSS_X64FRE_EN-US_DV9' (bootable)
# All 3 RKE2 nodes can mount and read.
# =============================================================================
apiVersion: v1
kind: PersistentVolume
metadata:
name: windows-server-2025-iso-nfs
labels:
flowercore.io/iso: windows-server-2025
flowercore.io/managed-by: bluejay-infra
spec:
capacity:
storage: 8Gi
accessModes:
- ReadOnlyMany
volumeMode: Filesystem
persistentVolumeReclaimPolicy: Retain
storageClassName: "" # static, no provisioner
mountOptions:
- nfsvers=4.1
- ro
- hard
- timeo=600
- retrans=3
nfs:
server: 10.0.58.3 # BlueJayNAS Synology DS1621+ on HOME VLAN 58
path: /volume1/ISOs/win2025-iso-disk
readOnly: true
---
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: windows-server-2025-iso-nfs
namespace: kubevirt-vms
labels:
app: ci-runner
flowercore.io/managed-by: bluejay-infra
spec:
accessModes:
- ReadOnlyMany
volumeMode: Filesystem
resources:
requests:
storage: 8Gi
storageClassName: ""
volumeName: windows-server-2025-iso-nfs